The HKVO stipulates: Since 1.12.22, only remotely readable measuring equipment may be installed.
Since December 1, 2022, only "remotely readable measuring devices that can be securely connected to a smart meter gateway [...]" may be installed in submetering systems. This is stipulated in the amendment to the Heating Costs Ordinance (HKVO), which came into force on December 1, 2021. This includes heat cost allocators, hot water meters, heat and cold meters, and optionally other meters and sensors.
These new requirements for measurement technology indicate that submetering systems will likely have to communicate via the smart meter gateway (SMGW) communication channel certified by the German Federal Office for Information Security (BSI) in the future, and thus comply with the BSI's protection profiles and technical guidelines. Minol already meets these high security requirements for measurement technology and data transmission for its customers.
The connection of metering equipment to smart meter gateways must comply with the guidelines of the Metering Point Operation Act (MsbG) as well as the protection profiles and technical guidelines (TR-03109-5) of the Federal Office for Information Security (BSI). For property owners and managers, this primarily means that they need a partner who guarantees legally compliant meter reading, transmission, and processing in the future.
Intelligent metering systems and connectivity to the Smart Meter Gateway
At Minol, we can already offer you the complete package for legally compliant billing according to the requirements of the Heating Costs Ordinance, including data transmission via the Smart Meter Gateway.
The system is based on an intelligent metering system (iMSys). This consists of a digital electricity meter (modern metering device) and a communication modem, the Smart Meter Gateway (SMGW). The intelligent metering system (iMSys) securely and encryptedly transmits the readings from the digital electricity meter via the SMGW. The digital electricity meters no longer need to be read on-site, as the devices automatically transmit the consumption data via the SMGW.
To transmit data from your properties, including data from your digital electricity meters, hot water meters, heat and cold meters, heat cost allocators, and optionally other meters and sensors, via the Smart Meter Gateway, a submeter unit or device (SME) is required. The CLS-enabled Minol Connect Gateway fulfills this function. It collects all data from the wireless metering equipment and forwards it securely and in compliance with regulations via the CLS interface of the Smart Meter Gateway.
The metering point operator is responsible for the installation and operation of the smart metering system. We ensure that your data is transferred securely and legally to the Minol billing system via the smart metering system. Minol has already developed all legally compliant solutions for you.
This is how smart meter gateways become intelligent metering systems.
In conjunction with the modern Minol Connect metering system, smart meter gateways can also transmit their meter readings and other data. Due to digitalization and the energy transition itself, the energy supply will fundamentally change. Mechanical electricity meters will become increasingly obsolete and will be replaced by electronic electricity meters.
Modern metering devices alone cannot yet digitally transmit meter readings to the metering point operator. A smart meter gateway (SMGW) will transmit meter readings and other data in the future. The smart metering device plus the smart meter gateway then form a smart metering system. The smart meter gateway is a communication unit with an integrated security module. On the one hand, it provides the user with transparency regarding their individual electricity consumption, and on the other hand, it securely transmits relevant data to an external market participant (EMT), such as the metering point operator.
The German Federal Office for Information Security (BSI) defines high standards for data protection and data security. A smart meter gateway must meet these requirements. Only smart meter gateways certified by the BSI may be used in smart metering systems.
What does this mean for you as a Minol customer?
As a Minol customer, you don't need to be intimidated by the high requirements of the latest heating cost regulations for data transmission via smart meter gateway, because
- Minol Connect can already be connected to the Smart Meter Gateway (SMGW) today,
- Minol has successfully tested this interface with all BSI-certified SMGWs via CLS interface (Controllable Local System) and
- Minol can be used to create the Accounting and for Interim consumption information all necessary data is obtained and processed from the SMGW.
If you have opted for the Minol Connect wireless system in the past , you are already on the safe side. When modernizing existing measuring equipment, we will only offer and install suitable devices.
contrastwerkstatt – stock.adobe.comHeating bill from a professional
Brunata Minol supports you with digital measurement technology and radio transmission and in providing interim consumption information via app – secure, digital and compliant with the German Heating Cost Ordinance (HKVO).
InsideCreativeHouse – AdobestockAlways up to date
* required fields